Fisher Torque Tube Displacer Level Transmitter
- Fisher
- Singapore
- 30 days
- 500 sets/month
1. Torque tube structure displacer level transmitter with more stable performance
2. Easy maintenance
3. Fisher 249W structure with more competitive price
4. Original DLC3100 transmitter import from Singapore and with operation button on it
Fisher Torque Tube Displacer Level Transmitter
• Intelligent :275 or 375(with HART) communication, with query, configuration, marking, testing and other functions.
The instrument communication is superimposed on 4~20 mA the same two-wire circuit, and the data communication can be carried out simultaneously without interrupting the process signal.
High sensitivity: Hall element sensor can detect trace angle signal, the instrument is suitable for small specific gravity, interface measurement.
Good stability: because the sealed Hall element can provide no interference signal, the built-in filter in the controller can filter out the interference of output signal due to liquid level fluctuation.
Strong anti-interference: because the controller shell and junction box are equipped with anti-electromagnetic interference filter, the anti-interference ability of the instrument is increased.
The measuring room part can have visual function, and the liquid level condition in the buoy can be observed directly through the visual part of the measuring room, which is convenient for the user to install, debug and use.
• Visual Float Appearance
Technical parameters of Fisher DLC3100 Torque Tube Displacer Level Transmitter
Supply voltage :12~30 V DC
Output signal :4~20 mA overlay HART protocol
Level of accuracy :0.5%,
Operating temperature :-100〜400°C
Temperature :-40~70C
Relative humidity :0~95 per cent
Nominal pressure :1.6〜42 MPa
Heat tracing pressure :0.6 MPa
Range :200~3000 mm (or special manufacture)
Minimum density or minimum density difference :>0.1 g/m3
Electrical connection: NPT 1/2" M20 x 1.5
Explosion-proof form: intrinsically safe Exia IICT 6; flameproof type: E x d IIC T 5Gb Class of protection: IP66
Calculation Formula of Liquid Buoyancy and Calculation Method of Comparison
1.Buoyancy calculation
Measuring liquid level | Symbol Content and Unit | Measuring boundary value |
厂 nD x H x p F 4 | D inner tube diameter | F = F - F nD2 x L x p1 F1= 4 nD2 x L x p2 F 4 |
cm H inner tube length | ||
Medium density g/cm p measuring liquid level3 | ||
Medium density g/cm p1 measuring liquid level3 | ||
Medium density g/cm p2 measuring liquid level3 | ||
When F liquid level is medium buoyancy, interface is medium buoyancy difference g | ||
F 1 medium buoyancy G F2 light medium buoyancy g |
2、Calculation method of calibration
a、 Water school law
Measuring liquid level | Symbol Content and Unit | Measuring boundary position |
L°=0 | L°cm of zero water level | L0=Hp2 |
LmHeight of full range water level cm | ||
cm H range |
Product selection for Fisher Torque Tube Displacer Level Transmitter
Model | Specification number | Content description | ||||||||
DLC3100- | DLC3100 level transmitter | |||||||||
DLCC3100SIS- | DLC3100 SIS SIL II level transmitter | |||||||||
Type | S | Field visual | ||||||||
Measureme nt methods | 1 | Level measurement | ||||||||
2 | Boundary survey | |||||||||
3 | Density measurements | |||||||||
Installation mode | A | Top | ||||||||
B | Top bottom | |||||||||
C | side by side | |||||||||
D | Bottom Side | |||||||||
E | Top Type | |||||||||
F | Side placement | |||||||||
Pressure rating | 2 | 1.6,2.0 MPa (Cass 150) | ||||||||
3 | 2.5 MPa | |||||||||
4 | 4.0 MPa | |||||||||
5 | 5.0 MPa (Class300) | |||||||||
6 | MPa 6.3 | |||||||||
10 | 10.0 MPa | |||||||||
11 | 11.0 MPa (Cass 600) | |||||||||
15 | 15.0MPa (Class 900) | |||||||||
16 | 16.0 MPa | |||||||||
25 | 25.0 MPa | |||||||||
26 | 26.0 MPa (Class1500) | |||||||||
42 | 42.0 MPa (Cass 2500) | |||||||||
Outer barrel material | T | Carbon steel | ||||||||
H | Stainless steel :0 Cr18Ni9(304) | |||||||||
R | Stainless steel :00 Cr17Ni14Mo2(316L) | |||||||||
F | Stainless steel PTFE | |||||||||
X | Other material (or according to actual material) | |||||||||
Working temperature | D | Medium temperature -20C~100C | ||||||||
G | Medium temperature 100C~400C | |||||||||
Explosion proof rating | i | Exi | ||||||||
D | flameproof | |||||||||
Annex | B | External tube heating | ||||||||
Scope of measureme nt | L | mm of measurement range |
Order requirement
mediun name and density
operation temperature and pressure
installation
material for cage and chamber, torque tube, inner displacer etc
flange sealing, rating
measurement scope
Packing and delivery of Fisher Torque Tube Displacer Level Transmitter