Guaranteeing the highest quality products has always been our pursuit

Fisher DLC3100 SIS SIL II Level Transmitter

  • Fisher DLC3100 SIS SIL II Level Transmitter
  • Fisher DLC3100 SIS SIL II Level Transmitter
  • Fisher DLC3100 SIS SIL II Level Transmitter
  • Fisher DLC3100 SIS SIL II Level Transmitter
  • Fisher DLC3100 SIS SIL II Level Transmitter
Fisher DLC3100 SIS SIL II Level Transmitter
  • Fisher
  • Singapore
  • 30 days
  • 500 sets/month

DLC3100SIS level transmitter with SIL II certificate.
The DLC3100 digital level controller with HART® communication uses different.
internal components, electronics, and covers than the DLC3010.
Import from Singapore.

 

  Fisher DLC3100 SIS SIL II Level Transmitter

fisher DLC3100 SIS

DLC3100 SIS WITH SIL II

SIL level transmitter

Emerson fisher DLC3100 digital level controller from Singapore

fisher level transmitter

DLC3100 SIS model with SIL II certificate ATEX explosion 4-20mA HART oRIGINAL FROM SINGAPORE WITH CO



fisher DLC3100 SIS

DLC3100

SIL level transmitter

Our stock over 500sets

fisher level transmitter

Question & Answer Checklist

1     Q:   Does the proposed modification cause any changes to the piping and instrumentation diagram (P&ID)?

A:   Only the instrument name changes from DLC3010 to DLC3100.

 

2     Q:   Does the proposed modification change process chemistry, technology, or operating and control philosophies?

A:   No.

3     Q:   Have the operating and design limits of the proposed modification changed?

A:   No.

 

4     Q:   Have the codes and standards to which the new equipment has been designed changed?

A:   No.

5     Q:   Does the proposed modification change the Hazardous Area Classification?

A:   No. Note that the I.S. entity parameters have changed. See Table 3.


6     Q:   Does the proposed modification introduce new equipment that needs to be operated and, has a new operations list been stated?

A:  The DLC3100 is operated the same as the DLC3010 digital level

controller.

 

7     Q:   Does the proposed modification introduce new equipment items    that require spare parts, training manuals, maintenance procedures or training to teach the maintenance department how to maintain  them?

A:  Yes. The standard components that may be required for maintenance

are different between the DLC3100 and DLC3010 digital level

controllers, except the mounting and lever assembly.

 

8     Q:   Does the proposed modification change the spares for existing pieces of equipment?

A:  Yes. The LCD and push button assemblies and electronics board are

different from DLC3010 digital level controller.

 

9     Q:   Does the proposed modification introduce new equipment items that require periodic predictive maintenance?

A:   No. The new equipment items that may require periodic maintenance

are the same as the old equipment.

 

FIELDVUE DLC3010 and DLC3100 level transmitter

Instrument Comparison

The DLC3100 digital level controller with HART® communication uses different

internal components, electronics, and covers than the DLC3010. This is detailed

below in Table 1.

 

DLC3010 Component

DLC3100

Front Cover Assembly (with push buttons and LCD board)

New

Main Electronics Board Assembly

New

Sensor Module

New

Lever Assembly

No Change

Housing

New

Terminal Box

New

Firmware

New

Table 1. Components Comparison Between the DLC3010 and DLC3100 Digital Level Controllers


 

 

The DLC3100 digital level controller front cover comes with push buttons and a liquid crystal display for user setup and calibration, without the need of an external

tool.

The main board and terminal assemblies are potted. Its modular design allows for easy replacement.

The sensor module is not field replaceable, as it requires factory calibration. There is a cover protecting the sensor module that has anti-tamper paint. This cover must

not be removed at any time to ensure accuracy.

The DLC3010 digital level controller adapter ring and terminal box are integrated in the DLC3100 digital level controller housing. The terminal box is on the side of the

housing and has two electrical conduit entries on the bottom. This bottom entry minimizes water ingress by self-draining when installed in its orientation.

The terminal assembly has six terminals. Three terminals on the left are for a Resistance Temperature Detector (RTD) connection, while the other three terminals on the right are for loop power. There are also two pins available for HART communication on the bottom right of the terminals.

Both the DLC3010 and DLC3100 digital level controllers use the same lever assembly. There is no change to the way that the lever assembly is coupled to the torque tube assembly. The threaded studs on the back of the housing allows the DLC3100 digital level controller to be mounted directly on a Fisher 249 sensor assembly.

 


Table 2: Features Comparison Among HART DLC3000 Series Digital Level Controllers

 

DLC3010 to DLC3100 Instrument Transition Design Comparison

Electrical – Entity parameters

 


Entity

DLC3010

DLC3100

Comment

Ui

30VDC

30VDC

No Change

Ii

226mA

130mA

-96mA

Pi

1.4W

0.9W

-0.5W

Ci

5.5nF

5.5nF

No Change

Li

0.4mH

0.01mH

-0.39mH




fisher DLC3100 SIS

SIL level transmitter


Packing and delivery for Fisher DLC3100 SIS SIL II Level Transmitter

fisher level transmitter



fisher DLC3100 SIS

About Us

Dandong Dedan Trade Co.,Ltd is the subsidiary of Dandong Premier Instrument which located in Dandong of China, professional produce each type of displacer level transmitters which fisher DLC3100 transmitters, foxboro 244LD transmitters,  other level gauges include glass plate gauge, magnetic level indicator, radar level transmitters, displacer level switch etc  welcome your inquiry





Download
Get the latest price? We'll respond as soon as possible(within 12 hours)

Privacy policy

close left right