DP Flow Meter For Oil Flow Measurement

- Dedan
- China
- 30 days
- 50 set/month
DP Positive displacement rotary vane flow meter belongs to positive displacement meter and is one of the most accurate measuring meters for measuring liquid of modern industry.
Positive Displacement Rotary Vane Flow Meter
Positive displacement rotary vane flow meter belongs to positive displacement meter and is one of the most accurate measuring meters for measuring liquid of modern industry. The flow meter has stable performance and is insensitive to flow state change of upstream medium and change of medium viscosity. It has high measuring accuracy,good applicability and long life. Now it has widely used for every field such as process control of modern industry and trade settlement, etc.
Main technical parameters DP Flow Meter For Oil Flow Measurement
1.Intrinsic Error:0.2%;0.5%
2.Nominal Diameter (mm):25mm;50mm;80mm;100mm;150mm;200mm;250mm;300mm;
3.Nominal Pressure:2.5MPa;4.0MPa; 6.4MPa;
4.Flow Rate Range:
Nominal Diameter | 25 | 50 | 80 | 100 | 150 | 200 | 250 | 300 | ||||||||
Intrinsic Error % | 0.2 | 0.5 | 0.2 | 0.5 | 0.2 | 0.5 | 0.2 | 0.5 | 0.2 | 0.5 | 0.2 | 0.5 | 0.2 | 0.5 | 0.2 | 0.5 |
Min. Flow m3/h | 3 | 1 | 8 | 5 | 25 | 18 | 35 | 25 | 60 | 40 | 100 | 80 | 120 | 110 | 300 | 200 |
Max. Flow m3/h | 6 | 8 | 20 | 35 | 65 | 80 | 90 | 115 | 120 | 150 | 180 | 240 | 350 | 550 | 900 | 1000 |
5.Operation Temperature: -20。C ~ +250。C;(special temperature should indicate.)
6.Fluid Viscosity: 0.6~500mPa.s ( kinematic viscosity)
7.Pressure loss: no more than 0.1MPa(such as nominal diameter is DN80)
8.Min. Indication Unit: For equipped with mechanical header, subject to the model of selected header.
For equipped with intelligent header: 0.001m3
9. Integrated Flux: For equipped with mechanical header, subject to the model of selected header.
For equipped with intelligent header: 99999.9999 m3
10. Coefficient of theoretical instrument: only for equipped with intelligent meter.
Nominal diameter DN | 25 | 50 | 80 | 100 | 150 | 200 | 250 | 300 |
Coefficient of theoretical instrument N/L | 18.868 | 6.993 | 3.657 | 2.357 | 1.634 | 1.483 | 0.841 | 0.563 |
Main features DP Flow Meter For Oil Flow Measurement
◆The meter can be equipped with mechanical integrating instrument to realize local indication, and can be equipped with pulse signal transmitter or intelligent instrument to realize signal remote transmission;
◆High precision, the highest accuracy class is 0.2;
◆Rotary vanes are wear-resistant, and the vanes can operate in high pressure condition.
◆The pressure loss is small. Attenuation of accuracy is low and the pressure loss is no more than 0.1Mpa. (Such as nominal diameter is DN80)
◆The structure of the single housing is simple and the weight is light, The structure of double housing can not be influenced by thermal expansion and pressure, and deformation is very small.
◆Installation for the meter is very convenient , no need for auxiliary equipment such as straight pipe section, rectifier, etc. The meter cannot be influenced by pipe pieces such as valves, elbow, etc.
◆The meter can work very stable with no vibration and noise.
◆the pressure drop is more than velocity-type flow meter, but is better than other positive displacement meter.
Model Selection Table DP Flow Meter For Oil Flow Measurement
Model | Code | Code meaning | ||||
LBTC- | Positive displacement rotary vane flow meter | |||||
25 | Nominal diameter:DN25mm | |||||
50 | Nominal diameter:DN50mm | |||||
80 | Nominal diameter:DN80mm | |||||
100 | Nominal diameter:DN100mm | |||||
150 | Nominal diameter:DN150mm | |||||
200 | Nominal diameter:DN200mm | |||||
250 | Nominal diameter:DN250mm | |||||
300 | Nominal diameter:DN300mm | |||||
Q | House material: nodular cast iron | |||||
C | House material: carbon steel | |||||
P | House material: 304 | |||||
2.5 | Nominal Pressure: 2.5MPa | |||||
4.0 | Nominal Pressure:4.0MPa | |||||
6.3 | Nominal Pressure:6.4MPa | |||||
JX | With mechanical counter, local indication. | |||||
BS | With mechanical counter, remote signal transmitted with pulse transmitter | |||||
ZN1 | With intelligent instrument, local indication; remote signal transmitted with pulse transmitter. | |||||
ZN2 | With intelligent instrument, local indication with 4~20mA signal output. | |||||
ZN3 | With intelligent instrument, local indication with 4~20mA signal output and remote signal transmitted with pulse signal transmitter | |||||
i | Intrinsically safe: ia IICT5 (for intelligent meter or pulse signal transmitter) | |||||
d | Explosion isolation: d IIBT4 (for intelligent meter or pulse signal transmitter) |
Order requirements
◆Specification:
◆Accuracy class:
◆Max. Min. flow value;
◆Fluid:
◆Operating temperature:
◆Fluid viscosity
◆Please note if the transmission distance is
more than 100m;
◆Brand of material contacting fluid:
◆Other flanges standard: